You can use the methods below to configure/access the card if you do not wish to use DHCP/BOOTP. If it is not configured on your DHCP server, the card will not accept an IP address. If using DHCP, a vendor cookie (DHCP Option 43) is required by default. In regards to Network Management Card 1 (AP9617, AP9618, AP9619) or devices with an embedded Network Management Card 1 (such as a AP78XX or AP79XX Rack PDU, Environmental Monitoring Unit, etc), there are three available options to configure the Network Management Card (NMC) with it's initial settings: the Wizard, terminal emulation (local/direct connection), and Address Resolution Protocol (ARP).ĭefault boot mode: DHCP/BootP - With DHCP Option 43 Vendor Cookie required to accept DHCP Offer.īy default, all of APC's Network Management Card 1 based devices are configured for a boot mode of DHCP/BOOTP. Network Management Card devices requiring reconfigurationĪ Network Management Card requires TCP/IP settings prior to being accessible via a network.Unconfigured Network Management Card-enabled devices.All firmware revisions (unless otherwise noted).Network Management Card 3 (NMC3) - AP9640, AP9641, AP9544ĭevices with an embedded Network Management Card 3 include (but are not limited to): Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX, APDU9), Rack Automatic Transfer Switches (AP44XXA), Smart-UPS Online (SRT).Network Management Card 2 (NMC2) - AP9630/AP9630CH, AP9631/AP9631CH, AP9635/AP9635CHĭevices with an embedded Network Management Card 2 include (but are not limited to): Early model 2G Metered/Switched Rack PDUs (AP84XX, AP86XX, AP88XX, AP89XX), Rack Automatic Transfer Switches (AP44XX), Certain Audio/Video Network Management Enabled products, Early model Smart-UPS Online (SRT).Network Management Card 1 (NMC1) - AP9617, AP9618, AP9619ĭevices with an embedded Network Management Card 1 include (but are not limited to): Metered/Switched Rack PDUs (AP78XX, AP79XX), Rack Automatic Transfer Switches (AP77XX, Environmental Monitoring Units (AP9320, AP9340, NetBotz 200).There are multiple configuration options available, outlined below, for each family of Network Management Cards or devices that have embedded versions of these products.ĭevices with an embedded Web/SNMP Card include (but are not limited to): Environmental Monitoring Unit 1 (AP9312TH) Once the cards have been configured with an IP address, Subnet Mask, and Default Gateway the cards can be accessed, managed, and controlled from other computers on the network. An APC Network Management Card must be configured with network settings before it can communicate on the network.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |